Print Back
For Industrial, Commercial and Residential Applications.

The Hydronic Series is a liquid-to-liquid heat exchanger designed for highly efficient heat transfer covering a wide variety of liquid types. The heavy duty design makes it ideal for demanding commercial, industrial and residential applications where high performance and low maintenance are important.

Heat transfer coefficients are greater than conventional shell and tube or plate exchangers because of the enhanced heat exchange surface and counter-flow design. Unlike plate heat exchangers, the Hydronic Series is not sensitive to debris clogging because of its large fluid circuits and is mechanically cleanable on the tube side circuit.
Liquid to Liquid Heat Exchangers
Liquid to Liquid Heat Exchangers - 2
Unit of Measure
1 

Item #

Item Name

Heat Transfer

Hot Connection Size

Cold Connection Size

CTD 4M2 N/A 100,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 100,000 Btu/hr N/A 1-1/8 in N/A 1-3/8 in
CTD 6M2 N/A 150,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 150,000 Btu/hr N/A 1-3/8 in N/A 1-5/8 in
CTD 8M2 N/A 200,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 200,000 Btu/hr N/A 1-5/8 in N/A 1-5/8 in
CTD 10M2 N/A 250,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 250,000 Btu/hr N/A 1-5/8 in N/A 2-1/8 in
CTD 12M2 N/A 300,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 300,000 Btu/hr N/A 1-5/8 in N/A 2-1/8 in
CTD 16M2 N/A 400,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 400,000 Btu/hr N/A 1-5/8 in N/A 2-1/8 in
CTD 20M2 N/A 500,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 500,000 Btu/hr N/A 2-1/8 in N/A 2-5/8 in
CTD 24M2 N/A 600,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 600,000 Btu/hr N/A 2-5/8 in N/A 3-1/8 in
CTD 36M2 N/A 900,000 British Thermal Units per Hour (Btu/hr) Non-Potable Liquid to Liquid Heat Exchanger N/A 900,000 Btu/hr N/A 2-5/8 in N/A 3-1/8 in
CUY 10M5 N/A 200,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 200,000 Btu/hr N/A 1-1/8 in N/A 1-1/8 in
CUY 15M5 N/A 300,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 300,000 Btu/hr N/A 1-1/8 in N/A 1-1/8 in
CUY 20M5 N/A 400,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 400,000 Btu/hr N/A 1-1/8 in N/A 1-1/8 in
CUY 25M5 N/A 500,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 500,000 Btu/hr N/A 1-3/8 in N/A 1-3/8 in
CUY 30M5 N/A 600,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 600,000 Btu/hr N/A 1-3/8 in N/A 1-3/8 in
CUY 35M5 N/A 700,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 700,000 Btu/hr N/A 1-5/8 in N/A 1-5/8 in
CUY 40M5 N/A 800,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 800,000 Btu/hr N/A 2-1/8 in N/A 2-1/8 in
CUY 45M5 N/A 900,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 900,000 Btu/hr N/A 2-1/8 in N/A 2-1/8 in
CUY 50M5 N/A 1,000,000 British Thermal Units per Hour (Btu/hr) Potable Liquid to Liquid Heat Exchanger N/A 1,000,000 Btu/hr N/A 2-1/8 in N/A 2-1/8 in
Unit of Measure